Measuring and diagnostic instrumentation, climate chambers:

  • Environmental chamber, LIB TH-50, volume 50L, temperature range -40oC – 150oC, humidity control
  • Climate chamber Neware MHW-25-S, volume 25L, temperature range 15oC – 60oC
  • Potentiostat/galvanostat Gamry Interface 5000P, 5A/6V, with EIS module (10µHz-20kHz).
  • Gamry Interface 1010E, 1A/12V, with EIS (10µHz-20kHz)
  • 4-channel potentiostat/galvanostat with EIS module, PalmSens MultiEmStat4.
  • MFIA Zurich instrument – impedance analyzer/LCR meter (5 MHz)
  • 2x battery cycler Neware BTS-4008T-5V12A-S1-F (8 channels, up to 12A, with temperature sensors)
  • 1x battery cycler Neware BTS-4008T-5V6A-S1-F (8 channels, up to 6A)
  • 2x battery cycler ZKETech EBC-A40L: 0-5V/40A
  • 2x battery cycler ZKETech EBC-A20: Charging 30V/5A, Discharging 30V/20A
  • 1x source MP3040D Professional: 0-30V / 0-40A
  • 1x power source – EA-EL 9080-510 A, 510A, 80V (15000W)
  • 1x load – EA-EL 9080-170 B, 170A, 80V (2400W)
  • Acoustic spectroscopy/defectoscopy – SIUI SyncScan UT2
  • 1x KEITHLEY 2602B (SMU up to 6A)
  • 1x Keithley 2281S-20-6 battery emulator
  • 1x Keysight DAQ973A data collection system + 1x DAQM900A + 1x DAQM901A + 1x DAQM903A + 1x DAQM907A
  • 1x spot welder
  • Explosion-proof thermal chamber 150L

Software tools:

  • COMSOL – multiphysics modeling, modules for battery systems
  • Matlab and Simulink

Technological equipment:

  • Chemical boxes
  • Chambers for hydrothermal synthesis
  • High-pressure press for forming pellets, 25 tons, MP250
  • High energy ball milling system with a controlled atmosphere